9.2 Bond Pad Guidelines

Bond Pad Guidelines

GUIDELINE NO.

DESCRIPTION

Wedge type Wire bond (without CUP)

Ball type Wire bond (with CUP)

Gold bump

Layer

Pad

PAD.1

Pad opening1

40

40

4

PAD.2

Pad opening to pad opening (1)

9

9

9

PAD.5

MetalTop (2) overlap of Top_Via (3)

0.5

0.5

0.5

PAD.6

MetalTop-1 (4) overlap of Top_Via (3)

0.5

0.5

0.5

PAD.7

Metal5 overlap of Via4

0.5

0.5

PAD.8

Metal4 overlap of Via4

0.5

0.5

PAD.9

Metal4 overlap of Via3

0.5

0.5

PAD.10

Metal3 overlap of Via3

0.5

0.5

PAD.11

Metal3 overlap of Via2

0.5

0.5

PAD.12

Metal2 overlap of Via2

0.5

0.5

PAD.13

Metal2 overlap of Via1

0.5

0.5

PAD.14

Metal1 overlap of Via1

0.5

0.5

PAD.15

Min pad opening space to nearest S/L guard ring

(Inner edge of GUARD_RING_MK marking)

30

30

30

PAD.16

Max pad opening space to nearest S/L guard ring

(Inner edge of GUARD_RING_MK marking)

200

200

NA

PAD.17

Pad opening space to active circuit COMP

15

NA

NA

PAD.18

Pad opening space to active circuit Poly2

15

NA

NA

PAD.19a

Pad opening to non-pad circuit Metal1, 2, 3, 4,5

Up to MetalTop-1

6

NA

NA

PAD.19b

Pad opening to non-pad circuit MetalTop

6

6

6

PAD.20

Pad metal to pad metal space

5

5

5

PAD.21

FOR other rules specific to CUP (circuit under pad

Case) refer to section 9.3

Note

  1. These are just default numbers for DRC purpose only, however, these are VARIABLE and the customer is advised to use the appropriate value acceptable to their assembly house.

  2. MetalTop is the last Metal of the product, for 4 layer metal product, MetalTop is Metal4.

  3. Top_Via: means the top most via for the product, For 6 layer metal product, Top_via will be Via5, while for 4 layer metal product, Top_Via will be Via3.

  4. MetalTop-1: means the one level lower than the last metal layer, For 6 layer metal product, MetalTop-1 will be Metal5, while for 4 layer metal product, MetalTop-1 will be Metal3.

  5. Those Via under Pad opening oversize by rule PAD.4 but exlcuding PAD will be checked by this rule.

  6. For wedge type pad metal is checked by metal1 to MetalTop interact with pad enclosed by Pad opening oversize by rule PAD.4, for ball type wire bond (with CUP) and gold bump, pad metal checked by MetalTop oversize by rule PAD.4 .

  7. Not recommended to use 6k top metal for cu wire bonding.

Bond Pad Bond Pad